Feed water parameters

Case-1: 5PV for 1 Pass systemCase-2: 5PV for each stage of 2 stages for 1 Pass systemCase-3: 5PV for each stage of 2 stages for 1 Pass system under pH 7 control + antiscalantsCase-4: 10 PV for 1 Pass systemCase-5: 15 PV for 1 Pass systemCase-6: 15PV for each stage of 2 stages for 1 Pass systemCase-7: 15PV for each stage of 2 stages for 1 Pass system under control pH 7 + antiscalantsCase-8: (15PV for Pass-1 system under control pH 7 + antiscalants) +(15 PV for each stage of 2 stages for Pass-2 system)Case-9: (15PV for Pass-1 system under control pH 7 + antiscalants) +(15 PV for each stage of 2 stages for Pass-2 system under pH control (9.0) w/ NaOH)Case-10: (15PV for Pass-1 system under control pH 7 + antiscalants) +(15 PV for each stage of 2 stages for Pass-2 system under pH control (9.5) w/ NaOH)Case-11: (15PV for Pass-1 system under control pH 7 + antiscalants) +(15 PV for each stage of 2 stages for Pass-2 system under pH control (10.0) w/ NaOH)Homework Assignments2Feed water: 100 m3/hRO recovery: 50%Feed water source: Standard seawater• Total dissolved solids (TDS): 35,984 mg/L• Estimated conductivity: 53,423 μS/cmTemperature: 25 ℃Number of stages: 1, 2#PV per stage: 5, 15Element type:• SEAMAXX-440 for Pass-1• BW30HRLE-440pH control• H2SO4to set pH 7.0 for 1 Pass systemAntiscalant: Na6P6O18(100) (3 mg/L recommended)RO Feed water parametersRO Pass configurations3 Due date: 29-October, until noon, Thursday Printing out All Cases’ running results and enclose your evaluation on:For cases of 1, 4, 51) TDS change in product water as PV increases.2) Pressure drop (ΔP) change as PV increases.3) Specific energy consumption (SEC) change over the applied pressure vessel.4) Draw a relationship graph of “permeate TDS” over “each element” in the applied PV.5) How do you think about the obtained above results?For cases of 1 and 21) TDS change in product water before and after 2 stages are made.2) Pressure drop (ΔP) change before and after 2 stages are made.3) Specific energy consumption (SEC) change before and after 2 stages are made.4) How do you think about the obtained above results?For cases of (2 and 3) and (6 and 7)1) Isn’t there any change in RO performance output after chemical treatment in RO feed water?For cases of 2 and 61) TDS change in product water in 2 stage system with different PV2) Pressure drop (ΔP) change in 2 stage system with different PV3) Specific energy consumption (SEC) change in 2 stage system with different PV4) How do think about the obtained above results?For cases of 7 and 81) TDS change in net product from RO system in two cases2) Specific energy consumption (SEC) change in two cases.For cases of 9, 10, 111) How are Boron concentrations changed in permeate water in pass-2 system as pHincreased by NaOH?2) Isn’t there any issue in RO performance as pH increased in 2 Pass RO system?

Sample Solution
Feed water parameters

Image result for Order Now images

CLICK HERE TO ORDER NOW!!

Leave a Reply

Your email address will not be published. Required fields are marked *